NIGPAS OpenIR
Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
Guo, Chao1; Li, Tao(李涛)2; Li, Gaojun1; Chen, Tianyu1; Li, Le1; Zhao, Liang1; Ji, Junfeng1
2022-11-02
发表期刊JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
ISSN0267-9477
卷号37期号:11页码:2470-2479
摘要

The precise determination of Cd isotope ratios via multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has made the widespread application of Cd isotopes possible. However, previous studies are complicated by the chemical purification method and molecular interferences from Zn (e.g.(ZnAr+)-Zn-70-Ar-36, (ZnAr+)-Zn-68-Ar-38, and (ZnAr+)-Zn-66-Ar-40 on Cd-106(+), (ZnAr+)-Zn-70-Ar-38 and (ZnAr+)-Zn-68-Ar-40 on Cd-108(+), (ZnAr+)-Zn-70-Ar-40 on Cd-110(+)). Separation of Zn from Cd requires the usage of a toxic reagent (HBr) and is also complicated by the relatively high procedural Zn blank especially when only a very small amount of Cd is available. Here we present a high-precision Cd isotope measurement method using double spike MC-ICP-MS, which avoids the molecular interferences from Zn introduced by both sample and chemical purification. A Cd-111-Cd-113 double spike pair optimized for the Cd-111, Cd-112, Cd-113, and Cd-114 inversion was used to correct for the mass bias. Elemental doping experiments suggest that the measured Cd isotope data were not significantly affected when the measured solution has, Zn/Cd < 10(3), Pd/Cd < 10(2), Fe/Cd < 10(-2), In/Cd < 10(-3), Sn/Cd < 10(-1), Zr/Cd < 10(-2), Nb/Cd < 10(-1), Mo/Cd < 10(-2), Ru/Cd < 10(-2), Ga/Cd < 10(-2), Ge/Cd < 10(-2), Se/Cd < 10(-1), and As/Cd < 10(-1). We thus modified the chemical purification method by removing the HBr step and eluting Zn and Cd together. The minimum requirement of sample size for precise measurement of stable Cd isotope ratios was tested to be as low as 10 ng. The measurements of pure Cd solutions (BAM I012 Cd and HPS Cd) give a long-term intermediate precision for delta Cd-114/110 relative to NIST SRM 3108 of 0.05 parts per thousand. We further validated our method by measuring different reference materials covering a relatively wide range of Zn/Cd (similar to 9 to 1239), the results of which agree within uncertainty with previous studies. Our study thus provides an efficient and precise way to determine stable Cd isotope ratios of geological samples with relatively low Cd concentrations.

DOI10.1039/d2ja00250g
收录类别SCI
语种英语
关键词[WOS]SOUTHERN-OCEAN ; CADMIUM ; FRACTIONATION ; POLLUTION ; SEAWATER ; SOILS ; ZINC ; ZN ; SIGNATURE ; CU
资助项目National Science Foundation of China[41991325] ; National Science Foundation of China[42030503] ; National Science Foundation of China[42002198] ; State Key Laboratory of Palaeobiology and Stratigraphy ; Strategic Priority Research Program of Chinese Academy of Sciences[XDB40010200]
WOS研究方向Chemistry ; Spectroscopy
WOS类目Chemistry, Analytical ; Spectroscopy
WOS记录号WOS:000870192200001
项目资助者National Science Foundation of China ; State Key Laboratory of Palaeobiology and Stratigraphy ; Strategic Priority Research Program of Chinese Academy of Sciences
出版者ROYAL SOC CHEMISTRY
文献类型期刊论文
条目标识符http://ir.nigpas.ac.cn/handle/332004/41332
专题中国科学院南京地质古生物研究所
通讯作者Li, Tao(李涛)
作者单位1.Nanjing Univ, Sch Earth Sci & Engn, MOE Key Lab Surficial Geochem, Nanjing, Peoples R China
2.Chinese Acad Sci, Nanjing Inst Geol & Palaeontol, State Key Lab Palaeobiol & Stratig, Nanjing, Peoples R China
通讯作者单位中国科学院南京地质古生物研究所
推荐引用方式
GB/T 7714
Guo, Chao,Li, Tao,Li, Gaojun,et al. Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS[J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY,2022,37(11):2470-2479.
APA Guo, Chao.,Li, Tao.,Li, Gaojun.,Chen, Tianyu.,Li, Le.,...&Ji, Junfeng.(2022).Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY,37(11),2470-2479.
MLA Guo, Chao,et al."Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS".JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY 37.11(2022):2470-2479.
条目包含的文件
条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Guo, Chao]的文章
[Li, Tao(李涛)]的文章
[Li, Gaojun]的文章
百度学术
百度学术中相似的文章
[Guo, Chao]的文章
[Li, Tao(李涛)]的文章
[Li, Gaojun]的文章
必应学术
必应学术中相似的文章
[Guo, Chao]的文章
[Li, Tao(李涛)]的文章
[Li, Gaojun]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。